Catalog navigation
CAD model selection
Selectable products: 2
HELP_VARIABLE
Company
Wilo
Description
Q15-84
Bill of material
0006082787/00001
PRODUKTABBILDUNG
Produktabbildung
ARTICLE_ID
Article number
ARTICLE_NAME
Type code
MANUFACTURER_NAME
Manufacturer
WILO SE
LOD
Level Of Detail
DESCRIPTION_SHORT
Short text
Submersible sewage pump with and without active cooling system for pumping untreated sewage for continuous duty in the stationary and portable wet well installation, as well as for stationary dry well installation.
DESCRIPTION_LONG
Tender text
Submersible sewage pump as submersible monobloc unit for stationary and portable wet well and dry well installation. Portable installation is possible, depending on type. Hydraulics The outlet on the pressure side is designed as horizontal flange connection. The maximum possible dry matter is 8 %. The following impeller shapes are currently used: *T = closed two-channel impeller *G = semi-open single-channel impeller *Q = semi-open two-channel impeller In the SOLID-G and SOLID-Q, the gap between suction port and impeller can be readjusted later. This ensures uniform hydraulic efficiency. Motor Submersible motors with passive and active cooling are used for the drive: *T motors (surface-cooled motors) have passive cooling. They emit their heat directly into the surrounding fluid via the housing parts. For this reason, these motors can operated immersed in continuous duty (S1), depending on performance, and non-immersed in short-time duty (S2). *FK, FKT and HC motors are self-cooling and have an active cooling system. The waste heat is guided via the coolant (white oil or water-glycol mixture) to an integrated heat exchanger, and this releases the waste heat to the conveyed medium. As a result, these motors are suitable for continuous duty (S1) either in immersed or non-immersed state. All motors have a sealing chamber that protects the motor from fluid ingress. It can be accessed from the outside and can be monitored with an optionally sealing chamber electrode. All filling fluids used are potentially biodegradable and environmentally safe. In addition, depending on performance, high-efficiency motors are also available: **Asynchronous motors with efficiency class of IE3* **Permanent magnet motors with an efficiency class of IE4/5* * (IE3/4 = based on IEC 60034-30, IE5 = based on IEC TS 60034-30-2) The cable inlet on the motors is longitudinally watertight, cable lengths can be individually configured. Seal Fluid-side and motor-side sealing is possible in the following versions depending on the motor type: *Version G: Two independently-acting mechanical seals *Version K: Block seal cartridge with two independently acting mechanical seals
PRODUCT_DESCRIPTION
Product description
ETIM_CLASS__EC_
ETIM Class (EC)
EC010733
INSTALLATION_TYPE
Installation type
TA
EF011795
Material motor housing
5.1301. EN-GJL-250
EF011796
Material quality motor housing
EN-GJL-250
EF023038
Pump casing material
Grey cast iron
EF023143
Quality class of pump casing
EN-GJL-250
EF011652
Material pump wheel
Ductile cast iron
EF024149
Material pump wheel
EN-GJS-500-7
EF014904
Volume flow rate (BEP)
0 m³/h
EF014905
Head at flow rate (BEP)
0 kPa
EF000991
Max. discharge flow
0 m³/h
EF000992
Max. static height
0 m
EF020449
Max. operating pressure
10.0 bar
EF003701
Electrical connection
Non-detachable
EF000536
Cable length
10.0 mm
EF003977
Rated voltage
V
EF000351
Number of phases
3
EF005455
Frequency
50 Hz
EF000001
Nominal current
A
EF012424
Motor power input (P1) per motor
kW
EF012425
Motor power output (P2) per motor
kW
EF023092
Insulation class acc. to IEC
H
EF001642
Rotational speed
1500.0 1/min
EF020121
Motor speed control
0
EF020120
Type of speed control
0
EF023182
Medium temperature (continuous)
3.0 °C
EF002386
Ambient temperature
3.0 °C
EF025118
Diameter of connection on delivery side
DN 150
EF025504
Outer pipe diameter connection outlet side
150 mm
EF026233
Flange compression stage connection outlet
PN 10 bar
EF014907
Connection standard outlet side
EN 1092-2
EF001339
Flange shape
Flange
EF023105
Max. dimension of fixed parts
78.0 mm
EF020293
With cutting system
no
EF015781
Nominal operating mode
S1
EF005474
Degree of protection (IP rating)
IP68
EF023089
Pump circuit
no
EF020289
Pump diameter
570.0 mm
EF023086
Pump height
0 mm
EF000493
Immersing depth
20.0 mm
EF004663
Explosion-proof
0
EF023157
Suitable for dry set-up
yes
EF000167
Weight
0 kg
EF016015
With protection against dry running
no
EF024286
Suitable for faeces
yes
EF025116
Connection on supply side
Flange
EF025117
Diameter of connection on supply side
DN 150
EF025503
Outer pipe diameter connection inlet side
150 mm
EF026143
Flange compression stage connection inlet
PN 10 bar
EF014906
Connection standard inlet side
EN 1092-2
EF011798
Type of impeller
SOLID-Q impeller
EF009598
Kind of motor starter
Frequency converter (FC)
EF008234
Type of motor protection
3 PTC-110°+1 PT100
PROT_SEALING_CHAMBER
Motor protection
-
EF003433__CABLE_1_
Cable construction
3x6/6KON mm²
EF003433__CABLE_4_
Cable construction
2x 2x0.5+4x0.5 mm²
EF000081__CABLE_1_
Cable type
S1BC4N8-F
EF000081__CABLE_4_
Cable type
HYBRID DATA
EF012492
Orientation
Horizontal connection
EF025977
Connection outlet side
Flange;DN150-PN10-EN1092-2
A1
Angle to first bolt hole
22.5 °
A0
Angle to first bolt hole
22.5 °
B1
Thickness flange (incl. sealing edge)
26 mm
D1
Outer diameter of flange
285 mm
D0
Outer diameter of flange
285 mm
D21
Diameter bolt hole
23 mm
D20
Diameter bolt hole
23 mm
D41
Diameter sealing edge
211 mm
DM
Diameter motor
299 mm
DN1
Diameter of connection on delivery side
DN 150
DN0
Diameter of connection on supply side
DN 150
DO1
Outer pipe diameter connection outlet side
150 mm
DO0
Outer pipe diameter connection inlet side
150 mm
F1
Thickness sealing edge
3 mm
H1
Height to centre connection
113 mm
K1
Pitch circle
240 mm
K0
Pitch circle
240 mm
L
Pump diameter
570 mm
L1
Connection length
0
N1
Number of bolt holes
8
N0
Number of bolt holes
8
W
Pump width side 1
508 mm
W1
Centre distance connection
0 mm
W2
Pump width side 2
284 mm
Z1
Working length
0
HHYD
Dimensions
197 mm
HMOT
Dimensions
930 mm
HA
Dimensions
32 mm
HB
Dimensions
165 mm
HC
Dimensions
0 mm
HD
Diameter pump housing
890 mm
DA
Dimensions
364 mm
DC
Dimensions
430 mm
L3
Dimensions
183 mm
R
Dimensions
20 mm
W3
Dimensions
140 mm
NCAB
Number of cables
2
Additional Information
Recommendations
Similar parts
Related Equipment
Additional Data
Catalog Vendor Locations
Loading ...
Previews
3D
Dimension
2D