您可通過問題反饋或聯繫在線客服提交您的建議,我們將盡快完善:
Support
確定
??
-
註冊
登錄
български
čeština
Deutsch
English (United Kingdom)
English (United States)
español
français
italiano
日本語
한국어
polski
português
русский
Türkçe
中文
中文 (繁體)
不支持第三方 Cookie
您的瀏覽器不允許設置第三方 cookie。Please enable them in your browsers settings or click the button below.
請單擊此處在新選項卡中打開頁面內容。
If the opened page does not work initially, try reloading the page.
Please enable cookies in your browser for PARTcommunity to work
CAD模型
登錄
註冊
български
čeština
Deutsch
English (United Kingdom)
English (United States)
español
français
italiano
日本語
한국어
polski
português
русский
Türkçe
中文
中文 (繁體)
Catalog navigation
所有產品目錄
幾何搜索
草圖搜索
變量搜索
認證的產品目錄
按照分類
按照國家
按照標準
可提供的產品目錄語言:
čeština
dansk
Deutsch
English
español
suomi
français
italiano
Nederlands
polski
português
русский
slovenščina
svenska
English (United States)
QA認證資訊
目錄: Wilo
Created: 23.04.2019
產品目錄的特殊屬性:
Central management with the CADENAS quality tool PARTproject QA
Electronic test run was passed (CAD compatibility assured)
Only clear nomenclature -> ERP-compatibility assured
Wilo
2540747
Wilo
Pressure-boosting systems
SiBoost Smart (FC) Helix V
Powered by
CAD模型選擇
{wilo/40288a8a54ce361f0154de0868d9789c/40288a8a54ce361f0154de0878150ae9/8ae2819c6e3493ed016e35c7461b2dd1.prj},{NB=SiBoost Smart FC 3 Helix V2204 2540747(350)_P1},{ARTICLE_ID=2540747},{EF023142=0},{EF023144=0},{EF000447=0},{EF020604=0},{EF023148=3},{EF014904=21.140},{EF014905=555.16},{EF000991=35.0},{EF000992=72.10},{EF020449=16.0},{EF000536=0},{EF003977=400},{EF000351=3},{EF005455=50},{EF000001=0.00},{EF012424=6.15},{EF012425=5.50},{EF001642=2900.0},{EF007178=0},{EF007179=0},{EF016383=0},{EF016385=0},{EF016386=0},{EF016387=0},{EF016388=0},{EF016389=0},{EF016390=0},{EF003626=0},{EF007521=0},{EF003055=0},{EF003052=0},{EF007525=0},{EF016391=0},{EF016392=0},{EF016393=0},{EF016394=0},{EF016395=0},{EF016396=0},{EF016397=0},{EF023182=3.0},{EF002386=5.0},{EF025503=50},{EF025504=50},{EF023149=0},{LOD=350}
請根據技術需求選擇所需產品. 可選屬性在表格中高亮顯示. 選擇可以通過點擊表格或數值來重置.
添加用於比較
可提供的產品: 294
HELP_VARIABLE
Company
Wilo
Description
With Frequency Converter
Bill of material
2540747
PRODUKTABBILDUNG
Produktabbildung
ARTICLE_ID
Article number
2540747
2540747
ARTICLE_NAME
Type code
SiBoost Smart FC 3 Helix V2204
SiBoost Smart FC 3 Helix V2204
LOD
Level Of Detail
350
300
200
350
300
200
MANUFACTURER_NAME
Manufacturer
WILO SE
DESCRIPTION_SHORT
Short text
Highly efficient water-supply unit ready for connection (non self-priming). With 2 to 4 vertically arranged glanded stainless steel high-pressure multistage centrifugal pumps from the Helix V series connected in parallel, including Smart Controller SC (available with and without frequency converter FC).
DESCRIPTION_LONG
Tender text
Compact pressure boosting system according to DIN 1988 and DIN EN 806, for direct or indirect connection. Consisting of non self-priming, switched in parallel, vertically-mounted stainless steel high-pressure multistage centrifugal pumps in glanded versions. Ready for connection with stainless steel pipework, mounted on a base frame, including control device with all necessary measurement and adjustment equipment. For fully automatic water supply and pressure boosting in residential, commercial and public buildings, hotels, hospitals, department stores and for industrial systems. For pumping drinking water, process water, cooling water, firefighting water (apart from fire-extinguishing systems in accordance with DIN 14462 and with the approval of the local fire protection authorities) or other types of industrial water that do not attack the materials either chemically or mechanically and do not contain abrasive or long-fibre constituents. Special features/product benefits *Heavy-duty system which satisfies all the requirements of DIN 1988 (EN 806) *WRAS/ KTW/ ACS approval of the pumps for all parts that come in contact with the fluid (EPDM version) *High-efficiency pump hydraulics of the Helix V series in connection with IE3 standard motor, including 0.75 kW and larger (optional for smaller motor power) *Bidirectional mechanical seals in the pumps for easy maintenance *Flexible lantern design permits direct access to the mechanical seal *The spacer coupling enables the mechanical seal to be replaced without dismantling the motor (from 7.5 kW) *Hydraulics of entire system are pressure-loss optimised *Parts that come in contact with the fluid are corrosion-resistant *Comfort control device SC-FC, maximum degree of control with symbol-based LC display, simple navigation with clear menu and Red Button Technology for parameter setting, including a frequency converter for continuous control of the base-load pump *Factory inspection and default setting at optimum operating range (incl. inspection certificate in accordance with EN 10204-3.1) Equipment/function *Stainless steel high-pressure multistage centrifugal pumps of the Helix V series *Base frame of electrolytically galvanised steel, with height-adjustable vibration absorbers for insulation against structure-borne noise *Shut-off device on the suction and pressure sides of each pump *Non-return valve on the pressure side of each pump *8 litre diaphragm pressure vessel, PN 16 including throughflow fitting in accordance with DIN 4807, pressure side *Pressure sensor (4 – 20 mA), pressure side *Pressure gauge, pressure side *Automatic pump control by means of a fully electronic Smart-Controller (SC-FC) in a sheet metal enclosure, protection class IP54 consisting of internal control voltage supply unit, microprocessor with soft PLC, frequency converter, analogue and digital inputs and outputs. A working area of 1 m around the system is recommended in order to facilitate the maintenance process. Operation/display *LC display (backlit) for display of the operating data, controller parameters, operating statuses of the pumps, error messages and history memory *Menu navigation with symbols and menu numbers *LEDs for display of the system status (operation/fault) *Factory-preset parameters for easy commissioning/start-up *Setting of operating parameters and acknowledgement of fault signals using Red Button Technology *Lockable main switch *Operation selectable with / without standby pump by customer service *Elapsed time indicator for each pump and for entire system *Switching cycle counter for each pump and for entire system *Fault log for the last 16 faults Control *Fully automatic control for 1 to 4 uncontrolled pumps by means of setpoint/actual value comparison *Frequency converter with sine filter for infinitely variable control of the base-load pump *Setpoint changeover: 2nd setpoint can be activated by contact *External setpoint adjustment via 4…20 mA signal *Automatic, load-sensitive cut-in of 1 to n peak-load pump(s) depending on the pressure - constant, p-c control variable *Contactors for switching on the pumps. SD versions include thermal triggering and a time relay for the star-delta combination *2 parameter sets selectable, easy menu (setpoint & control mode) or expert menu (operation and control parameters) *Operating mode of the pumps freely selectable (manual, off, automatic) *Automatic, configurable pump cycling **Standard setting: Impulse - The base-load pump is cycled at each new demand, regardless of operating hours **Alternative: Pump cycling dependent on operating hours, cycling of the base-load pump after the specified operating hours *Automatic, configurable pump test run (pump kick) **Can be activated/deactivated **Time between two test runs is freely programmable *Disabling times can be programmed as desired *Speed can be adjusted as desired Monitoring *Display of actual value of the system via a 0 – 10 Volt analogue signal for external measurement/display applications, 10 Volt correspond to the final sensor value *4 – 20 mA sensor signal (conductivity test of the sensor cable) for control variable actual value *Protection of the pump motors in the DOL version: via motor protection switch; in the SD version: Fuses in combination with thermal triggering *Automatic switchover to the standby pump in the event of an operating pump fault *Monitoring of maximum and minimum system values with adjustable time delays and limits *Zero-flow test for switching off the system when no water is being drawn off (adjustable parameters) *Pipe filling function for filling empty pipes (initial filling of the consumer network) *Protection against low water level via contact e.g. for float switch or pressure switch Interfaces *Potential-free contacts for SBM/SSM collective operation and collective fault signals *Logic reversal can be applied to SBM and SSM *Contacts for external on/off, low water and 2nd setpoint *External on/off via contact for deactivation of the system's automatic mode Optional accessories (factory installation or retrofitting after technical checks) *Manual-0-Automatic switch Preselection of the operating mode of each pump and manual operation in the event of a controller fault "Manual" (emergency/test mode available at mains power, motor protection available), "O" (pump switched off – cannot be switched on using the controller) and "Auto" (pump enabled for automatic mode via the controller) *Evaluation relay for PTC motor protection *Individual operation and fault signal, low-water signal *Signal converter for 0/2 –10 V to 0/4 – 20 mA *Soft starter for peak-load pumps *Connection to BMS in accordance with VDI 3814 Recommended accessories (to be ordered separately) *Optional WMS low-water cut-out switchgear kit *Flexible connection pipes or compensators *Break tank for system separation *Diaphragm pressure vessel *Threaded caps for systems with threaded joint tubing Bus systems (optional) *BACnet, LON bus, Modbus RTU Standards followed *Codes of practice for drinking water installations (TRWI) DIN 1988 (EN806) *Diaphragm pressure vessel/ diaphragm expansion tank DIN 4807 *Electronic equipment for use in power installations EN 50178 *Electrical equipment of machines EN 60204-1 *Safety of household and similar electrical appliances EN 60335-1 *Low-voltage switchgear and controlgear assemblies EN 60439-1/61439-1 *EMC interference resistance for industrial environments EN 61000-6-2 *EMC – Emission standard for residential, commercial and light-industrial environments EN 61000-6-3 (up to 9.0 kW, above this Emission standard for industrial environments EN 61000-6-4)
PRODUCT_DESCRIPTION
Product description
SiBoost Smart FC 3 Helix V2204
SiBoost Smart FC 3 Helix V2204
ETIM_CLASS__EC_
ETIM Class (EC)
EC010737
EF021265
Suitable for tap water
0
0
EF024284
Suitable for rainwater
false
EF025120
Suitable for sprinkling/irrigation
false
EF023038
Pump casing material
Grey cast iron
Grey cast iron
EF023143
Quality class of pump casing
EN-GJL-250
EN-GJL-250
EF011652
Material pump wheel
Stainless steel
EF024149
Material pump wheel
X2CrNi18-9
X2CrNi18-9
EF023142
Material fittings
0
EF023144
Material fittings
0
EF023489
Material of unit pipework
Stainless steel
EF023488
Quality class of unit pipework
X2CrNi18-9
EF000447
Reservoir material
0
EF020604
Quality class of reservoir
0
EF023148
Number of pumps
3
3
EF014904
Volume flow rate (BEP)
21.140
21.140
m³/h
EF014905
Head at flow rate (BEP)
555.16
555.16
kPa
EF000991
Max. discharge flow
35.0
35.0
m³/h
EF000992
Max. static height
72.10
72.10
m
EF020449
Max. operating pressure
16.0
bar
EF003701
Electrical connection
0
EF000536
Cable length
0
mm
EF003977
Rated voltage
400
400
V
EF000351
Number of phases
3
EF005455
Frequency
50
Hz
EF000001
Nominal current
0.00
A
EF012424
Motor power input (P1) per motor
6.15
6.15
kW
EF012425
Motor power output (P2) per motor
5.50
5.50
kW
EF023092
Insulation class acc. to IEC
F
EF001642
Rotational speed
2900.0
2900.0
1/min
EF020121
Motor speed control
None
EF020120
Type of speed control
Other
EF015266
Communication
0
EF007178
Radio standard Bluetooth
0
EF007179
Radio standard 2G / 3G / 4G
0
EF016383
Radio standard 2G / 3G / 4G
0
EF016385
Radio standard 5G
0
EF016386
Interface signal 0-10 V / 2-10 V
0
EF016387
Interface signal 0-20 mA / 4-20 mA
0
EF016388
Interface PT100 / PT1000 / PTC
0
EF016389
Interface Pulse Width Modulation (PWM)
0
EF016390
Interface pulse counter
0
EF003626
Potential free switch contact
0
EF007314
With communication interface RS-485
0
EF007312
With communication interface RS-232
0
EF007521
Supporting protocol for EtherNet/IP
0
EF003055
Supporting protocol for KNX
0
EF003052
Supporting protocol for PROFIBUS
0
EF007525
Supporting protocol for PROFINET IO
0
EF016391
Supporting protocol for CAN/CANOpen
0
EF016392
Supporting protocol for Modbus TCP
0
EF016393
Supporting protocol for Modbus RTU
0
EF016394
Supporting protocol for BACnet MS/TP
0
EF016395
Supporting protocol for BACnet IP
0
EF016396
Supporting protocol for LON/LONWorks
0
EF016397
Supporting protocol for LIN Bus
0
EF023182
Medium temperature (continuous)
3.0
°C
EF002386
Ambient temperature
5.0
°C
EF025116
Connection on supply side
Flange;DN50-PN16-EN1092-2
Flange;DN50-PN16-EN1092-2
EF025117
Diameter of connection on supply side
DN 50
DN 50
EF025503
Outer pipe diameter connection inlet side
50
50
mm
EF026143
Flange compression stage connection inlet
PN 16
PN 16
bar
EF014906
Connection standard inlet side
EN 1092-2
EN 1092-2
EF025977
Connection outlet side
Flange;DN50-PN16-EN1092-2
Flange;DN50-PN16-EN1092-2
EF025118
Diameter of connection on delivery side
DN 50
DN 50
EF025504
Outer pipe diameter connection outlet side
50
50
mm
EF026233
Flange compression stage connection outlet
PN 16
PN 16
bar
EF014907
Connection standard outlet side
EN 1092-2
EN 1092-2
EF001339
Flange shape
Flange
Flange
EF023149
Suction installation
0
EF023154
With bypass pipe
0
EF026396
Degree of protection (IP) pump
IP55
EF026395
Degree of protection cabinet (IP)
IP54
EF001438
Length
1700.0
1700.0
mm
EF000008
Width
1210.0
1210.0
mm
EF000040
Height
1900.0
1900.0
mm
EF000167
Weight
539.0
539.0
kg
EF008837
Approval
0
0
A1
Angle to first bolt hole
22.5
22.5
°
A2
Angle to first bolt hole
22.5
22.5
°
A3
Angle to first bolt hole
22.5
22.5
°
A4
Angle to first bolt hole
22.5
22.5
°
B1
Thickness flange (incl. sealing edge)
22
22
mm
B2
Thickness flange (incl. sealing edge)
22
22
mm
B3
Thickness flange (incl. sealing edge)
22
22
mm
B4
Thickness flange (incl. sealing edge)
22
22
mm
D1
Outer diameter of flange
220
220
mm
D2
Outer diameter of flange
220
220
mm
D3
Outer diameter of flange
220
220
mm
D4
Outer diameter of flange
220
220
mm
D21
Diameter bolt hole
18
18
mm
D22
Diameter bolt hole
18
18
mm
D23
Diameter bolt hole
18
18
mm
D24
Diameter bolt hole
18
18
mm
D41
Diameter sealing edge
156
156
mm
D42
Diameter sealing edge
156
156
mm
D43
Diameter sealing edge
156
156
mm
D44
Diameter sealing edge
156
156
mm
DE
Diameter expansion vessel
206
mm
DM
Diameter motor
210
210
mm
DN1
Diameter of connection on supply side
DN 100
DN 100
mm
DN2
Diameter of connection on supply side
DN 100
DN 100
mm
DN3
Diameter of connection on delivery side
DN 100
DN 100
mm
DN4
Diameter of connection on delivery side
DN 100
DN 100
mm
DO1
Outer pipe diameter connection inlet side
0.0
DO2
Outer pipe diameter connection inlet side
0.0
DO3
Outer pipe diameter connection outlet side
0.0
DO4
Outer pipe diameter connection outlet side
0.0
F1
Thickness sealing edge
3.0
3.0
mm
F2
Thickness sealing edge
3.0
3.0
mm
F3
Thickness sealing edge
3.0
3.0
mm
F4
Thickness sealing edge
3.0
3.0
mm
H
Height
1900
1900
mm
H02
Distance to bottom side vessel
332.25
332.25
mm
H1
Height to centre connection
195
195
mm
H2
Height to centre connection
195
195
mm
H3
Height to centre connection
195
195
mm
H4
Height to centre connection
195
195
mm
H5
Height expansion vessel
297
mm
H6
Height electrical cabinet
1900
1900
mm
HP
Pump height
966
966
mm
K1
Pitch circle
180
180
mm
K2
Pitch circle
180
180
mm
K3
Pitch circle
180
180
mm
K4
Pitch circle
180
180
mm
L
Length of foundation plate
900
900
mm
L1
Connection length
150
150
mm
L2
Connection length
750
750
mm
L3
Connection length
150
150
mm
L4
Connection length
750
750
mm
LE1
Distance till side foundation plate
150
150
mm
LE2
Centre-to-centre (double) pump
300
300
mm
LE3
Thickness electrical cabinet
800
800
mm
LE4
Width electrical cabinet
400
400
mm
LE5
Length to top side electrical cabinet
149
149
mm
LE6
Length electrical cabinet
110
110
mm
LE7
Distance to side cabinet
0
mm
LE8
Width electrical cabinet 1
110
110
mm
LE9
Length 9
25
25
mm
N1
Number of bolt holes
8
8
N2
Number of bolt holes
8
8
N3
Number of bolt holes
8
8
N4
Number of bolt holes
8
8
NP
Number of pumps
3
3
Q1
Length gusset/thread
0
0
mm
Q2
Length gusset/thread
0
0
mm
Q3
Length gusset/thread
0
0
mm
Q4
Length gusset/thread
0
0
mm
S1
Wall thickness connection
0
0
mm
S2
Wall thickness connection
0
0
mm
S3
Wall thickness connection
0
0
mm
S4
Wall thickness connection
0
0
mm
W1
Centre-to-centre distance of connections
990
990
mm
W2
Foundation plate width
450
450
mm
W3
Distance backside cabinet
0
HD
Diameter pump housing
203
203
mm
H01
Dimensions
105
105
mm
L5
Dimensions
300
300
mm
W0
Dimensions
1210
1210
mm
Additional Information
建議
Similar parts
相應設備
Additional Data
Catalog Vendor Locations
No recommendations available.
Previews
3D
尺寸
2D
下載CAD模型
生成CAD模型